RosettaCNC plugin Modbus
Information
Document: | MDUROSETTACNCMODBUS | ||
---|---|---|---|
Description: | RosettaCNC Modbus inteface | ||
Link: | http://wiki.rosettacnc.com/en/software/rosettacncmodbus | ||
Release documento | Descrizione | Note | Data |
01 | First release | / | 22/10/2020 |
02 | Align with 1.9.2 release | / | 28/04/2021 |
03 | Fix IR_GCODE_CMD address and add IR_EXECUTION_INFO info | / | 05/10/2021 |
Introduction
The RosettaCNC board has a MODBUS® SLAVE server inside to exchange information with a PLC. This function is interesting for implementing machine logic inside the PLC.
The implemented protocol is MODBUS® SLAVE TCP. Port, slave id and refresh time can be set in Board settings panel.
The server share the same IP address used by the card for connection to the software on the PC.
The interface contract between the MODBUS® SLAVE in the CNC board and the product that will implement the MODBUS® MASTER connection is bound to the parameter IR_MODBUS_INTERFACE_LEVEL. The first operation to do as soon as communication with the SLAVE is accessed is to retrieve the contents of this register and adapt the subsequent requests to the relative data table model.
The MODBUS_INTERFACE_LEVEL version 1 is currently available.
In the installation package there is the “extra \ modbusview” folder with a .NET example compiled with Visual Studio 2017 Community version with which it is possible to see how easy it is to access the data of the RosettaCNC card by creating a MODBUS® Master.
What you can do with modbus interface ?
Monitor CNC state
Reading INPUT registers you can monitor the CNC state: positions, state, alarms, gcode line during execution, etc
Activate Alarms/Warnings
Writing on HR_CUSTOM_ALARM_xx or HR_CUSTOM_WARNING_xx you can active an alarm/warning. There are max 8 alarms and 8 warnings. Alarm text can be set in CNC control software and is multi language.
Exchange data with Gcode
Bi directinal shared memory is provided. Gcode can write values that can be so visible to the modbus (see G100 P1000 and IR_SHARED_MEMORY registers). Modbus can write values that can be visible to the Gcode (see M167 P1000 and HR_SHARED_MEMORY registers).
Take care that shared memory is retentive so PLC have to context values with CNC states and other informations.
I/O expansion
Use virtual inputs / outputs concept to expando CNC I/O. In this case PLC have only to copi modbus data to real electrical resource.
Function control
Use vitual inputs outputs concept to operate with normal I/O feature. For example if you want PLC to start a Gcode execution, map the Start input function on first virtual input. When PLC active the relative virtual bit CNC starts execution.
If you want to inform PLC about AUX2 output state, map AUX2 to a virtual outputs.
Registers Table
; modbus input registers table IR_MODBUS_INTERFACE_LEVEL 30001 ; input register [W]: modbus interface level IR_FIRMWARE_VERSION 30002 ; input register [W]: firmware version: ; b15..b08 = version ; b07..b00 = release IR_SERIAL_NUMBER 30003 ; input register [L]: serial number IR_MACHINE_POSITION_X 30005 ; input register [L]: machine position X [mm/1000] IR_MACHINE_POSITION_Y 30007 ; input register [L]: machine position Y [mm/1000] IR_MACHINE_POSITION_Z 30009 ; input register [L]: machine position Z [mm/1000] IR_TARGET_POSITION_X 30011 ; input register [L]: target position X [mm/1000] IR_TARGET_POSITION_Y 30013 ; input register [L]: target position Y [mm/1000] IR_TARGET_POSITION_Z 30015 ; input register [L]: target position Z [mm/1000] IR_TARGET_POSITION_A 30017 ; input register [L]: target position A [°/1000] IR_TARGET_POSITION_B 30019 ; input register [L]: target position B [°/1000] IR_TARGET_POSITION_C 30021 ; input register [L]: target position C [°/1000] IR_PROGRAM_POSITION_X 30023 ; input register [L]: program position X [mm/1000] IR_PROGRAM_POSITION_Y 30025 ; input register [L]: program position Y [mm/1000] IR_PROGRAM_POSITION_Z 30027 ; input register [L]: program position Z [mm/1000] IR_PROGRAM_POSITION_A 30029 ; input register [L]: program position A [°/1000] IR_PROGRAM_POSITION_B 30031 ; input register [L]: program position B [°/1000] IR_PROGRAM_POSITION_C 30033 ; input register [L]: program position C [°/1000] IR_WORKING_OFFSET_X 30047 ; input register [L]: working offset X [mm/1000] IR_WORKING_OFFSET_Y 30049 ; input register [L]: working offset Y [mm/1000] IR_WORKING_OFFSET_Z 30051 ; input register [L]: working offset Z [mm/1000] IR_WORKING_OFFSET_A 30053 ; input register [L]: working offset A [°/1000] IR_WORKING_OFFSET_B 30055 ; input register [L]: working offset B [°/1000] IR_WORKING_OFFSET_C 30057 ; input register [L]: working offset C [°/1000] IR_ACT_VELOCITY_X 30059 ; input register [L]: actual velocity X [mm/min] IR_ACT_VELOCITY_Y 30061 ; input register [L]: actual velocity Y [mm/min] IR_ACT_VELOCITY_Z 30063 ; input register [L]: actual velocity Z [mm/min] IR_ACT_VELOCITY_A 30065 ; input register [L]: actual velocity A [°/min] IR_ACT_VELOCITY_B 30067 ; input register [L]: actual velocity B [°/min] IR_ACT_VELOCITY_C 30069 ; input register [L]: actual velocity C [°/min] IR_MAIN_CNC_STATE 30071 ; input register [W]: main cnc state ; 0: Init ; 1: Init Fieldbus ; 2: Alarm ; 3: Idle ; 4: Homing ; 5: Jog ; 6: Run ; 7: Pause ; 8: Limit ; 9: Measuring tool offset ; 10: Scan 3D ; 11: Safety Idle ; 12: Change Tool ; 13: Safety ; 14: Waiting Main Power ; 15: Retract tool IR_CNC_STATES 30072 ; input register [W]: cnc states ; b00: AllAxesHomed ; b01: ProgramExecutionEndedSuccesfully IR_ALARM_CODE 30073 ; input register [W]: alarm code IR_ALARM_INFO_FIELD_A 30074 ; input register [W]: alarm info field A IR_ALARM_INFO_FIELD_B 30075 ; input register [W]: alarm info field B IR_GCODE_LINE 30076 ; actual gcode line [L] IR_EXECUTION_INFO 30078 ; b00-b07: buffer level [%], b08-b15: program transferred [%] IR_VIRTUAL_OUTPUTS 30079 ; virtual outputs 1 to 16 mask ; b0 = virtual outputs 1 ; b1 = virtual outputs 2 ; ... ; b15 = virtual outputs 16 IR_SHARED_MEMORY_01 30080 ; shared memory 32 bit G100 P1000 A parameter IR_SHARED_MEMORY_02 30082 ; shared memory 32 bit G100 P1000 B parameter IR_SHARED_MEMORY_03 30084 ; shared memory 32 bit G100 P1000 C parameter IR_SHARED_MEMORY_04 30086 ; shared memory 32 bit G100 P1000 D parameter IR_SHARED_MEMORY_05 30088 ; shared memory 32 bit G100 P1000 E parameter IR_SHARED_MEMORY_06 30090 ; shared memory 32 bit G100 P1000 F parameter IR_SHARED_MEMORY_07 30092 ; shared memory 32 bit G100 P1000 H parameter IR_SHARED_MEMORY_08 30094 ; shared memory 32 bit G100 P1000 I parameter IR_GCODE_CMD 30096 ; actual gcode command [L] ; modbus holding registers table HR_CUSTOM_ALARM_01 40001 ; set to non zero to sign custom alarm 01 HR_CUSTOM_ALARM_02 40002 ; set to non zero to sign custom alarm 02 HR_CUSTOM_ALARM_03 40003 ; set to non zero to sign custom alarm 03 HR_CUSTOM_ALARM_04 40004 ; set to non zero to sign custom alarm 04 HR_CUSTOM_ALARM_05 40005 ; set to non zero to sign custom alarm 05 HR_CUSTOM_ALARM_06 40006 ; set to non zero to sign custom alarm 06 HR_CUSTOM_ALARM_07 40007 ; set to non zero to sign custom alarm 07 HR_CUSTOM_ALARM_08 40008 ; set to non zero to sign custom alarm 08 HR_CUSTOM_WARNING_01 40009 ; set to non zero to sign custom warning 01 HR_CUSTOM_WARNING_02 40010 ; set to non zero to sign custom warning 02 HR_CUSTOM_WARNING_03 40011 ; set to non zero to sign custom warning 03 HR_CUSTOM_WARNING_04 40012 ; set to non zero to sign custom warning 04 HR_CUSTOM_WARNING_05 40013 ; set to non zero to sign custom warning 05 HR_CUSTOM_WARNING_06 40014 ; set to non zero to sign custom warning 06 HR_CUSTOM_WARNING_07 40015 ; set to non zero to sign custom warning 07 HR_CUSTOM_WARNING_08 40016 ; set to non zero to sign custom warning 08 HR_SHARED_MEMORY_01 40018 ; shared memory 32 bit M167 P1000 (#5740) HR_SHARED_MEMORY_02 40020 ; shared memory 32 bit M167 P1000 (#5741) HR_SHARED_MEMORY_03 40022 ; shared memory 32 bit M167 P1000 (#5742) HR_SHARED_MEMORY_04 40024 ; shared memory 32 bit M167 P1000 (#5743) HR_SHARED_MEMORY_05 40026 ; shared memory 32 bit M167 P1000 (#5744) HR_SHARED_MEMORY_06 40028 ; shared memory 32 bit M167 P1000 (#5745) HR_SHARED_MEMORY_07 40030 ; shared memory 32 bit M167 P1000 (#5746) HR_SHARED_MEMORY_08 40032 ; shared memory 32 bit M167 P1000 (#5747) HR_VIRTUL_INPUTS 40034 ; virtual inputs 1 to 16 (mask) ; b0 = virtual inputs 1 ; b1 = virtual inputs 2 ; ... ; b15 = virtual inputs 16
Notes
- To guarantee the atomicity of the LONG data (32bit), the CNC set busy status during the internal updating of the registers. If a MODBUS® MASTER tries to access the information as long as the SLAVE is in the busy state, it will obtain the BUSY state and must remain in polling so that the SLAVE is not unlocked.
- If you want to use holding registers data you have to set “Enable write operations” in Board settings panel.
- Take care that shared memory is retentive so PLC have to context values with CNC states and other informations.
Limitation
To optimize the internal data retrieval operations, the SLAVE supports the multiple reading of INPUT register and HOLDING register for a maximum of 32 registers at a time.