Differenze

Queste sono le differenze tra la revisione selezionata e la versione attuale della pagina.

Link a questa pagina di confronto

Entrambe le parti precedenti la revisione Revisione precedente
software:features_g-code:messages_media [2019/11/07 13:48]
cnc205 [24.1 Parameters meaning]
software:features_g-code:messages_media [2020/01/09 14:16] (versione attuale)
cnc205 [24.1 Parameters meaning]
Linea 8: Linea 8:
  
 ===== - Parameters meaning ===== ===== - Parameters meaning =====
-  ​* ''​P''​ the text to be displayed for M109 and the path to the image to be displayed using M120.+ 
 +  ​* ''​P''​ the text to be displayed for ''​M109'' ​and the path to the image to be displayed using ''​M120''​.
   * ''​Q''​ the optional window type to be used to display the message or the media. The following types are available:   * ''​Q''​ the optional window type to be used to display the message or the media. The following types are available:
-    * 0: modal window with an OK button. +    * 0: modal window with a Resume ​button. 
-    * 1: modal window with an Abort button. +    * 1: modal window with a Stop button. 
-    * 2: modal window with an OK button ​and an Abort button.+    * 2: modal window with a Stop and Resume ​button.
     * 3: modal window where the user can insert a value that will be stored in parameter ''#​5721''​.     * 3: modal window where the user can insert a value that will be stored in parameter ''#​5721''​.
     * 4: message will be displayed in the HUD.     * 4: message will be displayed in the HUD.
   * ''​D''​ the optional default value to be used when ''​Q''​ is set to 3. The specified is used to generate the initial preview.   * ''​D''​ the optional default value to be used when ''​Q''​ is set to 3. The specified is used to generate the initial preview.
  
-A special case of M109 is ''​M109 p"user error message"​ Q-1''​ used to stop compilation reporting a custom error message placed between double quotes.\\ +A special case of ''​M109'' ​is ''​M109 p"user error message"​ Q-1''​ used to stop compilation reporting a custom error message placed between double quotes.\\ 
-When no message is present after M109 (Eg: ''​m109 q-1''​) the default text ''​[E0345] in line x - generic user error with m109 q-1''​ will be showed.+When no message is present after ''​M109'' ​(Eg: ''​M109 Q-1''​) the default text ''​[E0345] in line x - generic user error with m109 q-1''​ will be showed.
  
 === Notes === === Notes ===
  • Ultima modifica: 2020/01/09 14:16
  • da cnc205