en:lib:tpl:tpl-h-cnalim-010

The wiring must be carried out by specialized personnel and provided with appropriate anti-static measures.
Before handling the instrument, remove voltage and all parts connected to it.
To ensure with the CE compliance, The supply voltage must have a galvanic insulation of at least 1500 Vac.

Available power supplies 24 Vdc
Valid range 22 รท 27 Vdc
Max. absorption @power@W

Connector

CN1 TerminalSymbolDescription
1 Positive power supply
2 GROUND Ground-PE (signals)
3 0V power supply

Connection examples

Is prescribed the use of insulated power supply with 24Vdc output complies with EN60950-1.

Use two separate power supplies: one for the control part and one for the power part
In the case of a single power supply, Use two separate lines: one for control and one for power
Do not use the same lines as the power part
  • Last modified: 2023/03/22 09:07
  • by 127.0.0.1